| 详细内容 | Dear, We experienced high vibration in our centrifugal pump due to piping configuration is installed with miss-alignment and there is problems to rectify it.
 The issue is to install the flexible expansion joints in both suction and discharge pump flanges to isolate the piping configuration problems than the pump.
 The following data maybe help you to submit the proper joints
 The pump in/outlet is 12 flange
 The piping to/from the pump is 16 pipeline
 The working discharge pressure is 105 Bar @ 120 oC
 The suction pressure is 7 Bar
 The min/max flow rate 300/700 M3/Hr.
 The medium is lean solution potassium carbonate in BENFIELD process
 The driving power is 2.4 MW
 Best regards.
 
 Country:Egypt
 
 
 |  
| 联系方式 | Co:Shell-Egypt (BAPETCO) Add:127 ABD EL AZIZ FAHMY, HELIOPOLIS, CAIRO, EGYPT, Egypt
 Tel:20-2-22925993
 Fax:20-12-4497240
 Email:a.shoukry@bapetco.simis.com
 LinkMan:Aly Shoukry
 |  
|  |  |  |  |